Jual PH Meter HANNA HI98118 GroLine Waterproof Hydroponic pH Tester TLP/WA 082217294199
Untuk Pemesanan dan Informasi Harga

 Asep Tantan
Jlan H Kelik No.20 Kelapa Dua Kebun Jeruk Jakarta Barat 11550
Phone 1 : 021.22054159
Phone 2 : 082112325856
Phone 3 : 0822.1729.4199 bisa WA
email : atantan.margasetia@gmail.com
web :  www.tantanteknik.com
www.warungsirinejakarta.blogspot.com
www.warungjakartasurvey.wordpress.com

KAMI MELAYANI PEMESANAN KESELURUH KOTA-KOTA DI INDONESIA,
Bali, Sidoarjo, Malang, Semarang, Yogyakarta, Pekalongan, Cirebon, Tangerang, Jakarta, Sumatra, Aceh, Lampung, Riau, Batam, Surabaya, Bandung, Medan, Jambi, Padang, Kalimantan, Samarinda, Pekanbaru, Bengkulu, Makasar, Sulawesi, Irian jaya,Papua, Bangka Belitung, Banten, Jabar, Jateng, Jatim, Ntt, Ntb, Gorontalo, maluku DLL
Pengiriman Untuk Kota Jakarta Gratis. Luar Jakarta dengan layanan JNE,TIKI, KARGO, dan Exspedisi lainnya

Deskripsi
The GroLine HI98118 pH/temperature tester is our latest pocket meter for measuring the pH of a hydroponic nutrient solution. This modern looking meter is only 0.7" thick and extremely ergonomic, fitting comfortably in your hand. The HI98118 has a very large easy to read LCD display that shows both pH and temperature along with calibration, stability and low battery indicators. All operations are simplified to two buttons. One is for turning the meter on/off and the other for automatic one or two point calibration.
  • Two-Button Operation
  • Quick Calibration Mode using Hanna Quick Cal pH/EC Calibration Solution
  • Extractable Cloth Junction to Extend pH Electrode Life 

Details





The HI98118 GroLine pocket pH Tester is an affordable way to measure the pH of hydroponic nutrient solutions. The maintaining of an optimal pH is essential to maximize optimum growth. The general rule of thumb is that as pH increases the solubility of minerals and nutrients decrease. It is important that nutrients are soluble for plants to uptake and use for growth. The pH of nutrient solution can also affect the bacteria that fix nitrogen for the plant to use. Every plant has optimum pH levels for growth. Below is a table for the ideal pH range for a variety of plants.
The HI98118 can be used to measure the pH in soils as well as nutrient solutions. The North Carolina State University has outlined a procedure known as  This method is used for container plants in which 50 ml of leachate is collected from a thoroughly watered plant and then tested.
To measure the pH of soil as a slurry the  recommends a mixture of 1 part soil to 1 part water. The slurry is allowed to rest for 10 minutes so that the solids will settle out and the pH of liquid above can be measured.
The HI98118 is an advanced meter while maintaining simplicity. The front of the meter has two buttons. One is for turning the meter on and off while the other is used to enter the calibration mode. There is a third button in the battery compartment that allows the user to customize the meter to their preference. Customization includes temperature readout in oC or oF, automatic shut off selectable from 8 minutes, 60 minutes or disabled, and lastly the choice of using Hanna's Quick Cal pH/EC standard or traditional buffers values of pH 4.01, 7.01 and 10.01.
The HI98118 features a unique extractable cloth junction. The reference junction of a pH electrode, also known as a salt bridge, provides an electrical pathway between the internal reference cell and the sample. Any clogging of the junction will result in a disruption of the electrical pathway. When this happens the readings will be erratic and take a very long time to stabilize. With the Hanna extractable junction a small portion of 1/8" is extracted or pulled to expose a clean surface. With the junction renewed the clogging is cleared allowing the meter to still be used. The overall length of the junction is about 1" so the junction should only be extracted periodically

Features at-a-glance

  • Built in temperature sensor for Automatic Temperature Compensated measurements.
  • Renewable junction to clear any clogging that causes readings to drift and be erratic .
  • Stability indicator that disappears once a stable reading is obtained .
  • Automatic calibration to one or two points at a push of a button.
  • Uses Hanna's Quick Cal pH/EC standard with a pH value of 6.86. The standard can also be used to calibrate conductivity meters to 5,000 μS/cm .
  • Battery % level remaining displayed at start up.
  • Low battery indicator that is displayed when less than 10% battery life is remaining.

 

Optimum pH Levels for Plants

Vegetable Plants
Optimal pH
Garden/Flower Plants
Optimal pH Orchard Plants Optimal pH 
Artichoke
6.5-7.5
Acacia
6-8
Apple
5-6.5
Asparagus
6-8
Acanthus
6-7
Apricot
6-7
Barley
6-7
Amaranth
6-6.5
Apricot
6-7
Bean
6-7.5
Bougainvillea
5.5-7.5
Cherry
6-7.5
Brussels Sprout
6-7.5
Dahlia
6-7.5
Grapefruit
6-7.5
Corn (Maize)
6-7.5
Erica
4.5-6
Grapevine
6-7
Cucumber
5.5-7.5
Euphorbia
6-7
Lemon
6-7
Early carrot
5.5-7
Fuchsia
5.5-7.5
Nectarine
6-7.5
Early Potato
4.5-6
Gentian
5-7.5
Orange
5-7
Egg Plant
5.5-7
Gladiolus
6-7
Peach
6-7.5
Late carrot
5.5-7
Hellebore
6-7.5
Pear
6-7.5
Late Potato
4.5-6
Hyacinth
6.5-7.5
Plum
6-7.5
Lettuce
6-7
Iris
5-6.5
Pomegranate
5.5-6.5
Melon
5.5-6.5
Juniper
5-6.5
Walnut
6-8
Oat
6-7
Ligustrum
5-7.5

Onion
6-7
Magnolia
5-6


Pea
6-7.5
Narcissus
6-8.5


Pepper
6-7
Oleander
6-7.5

Pumpkin 5.5-7.5
Paulownia
6-8


Rice
5-6.5
Portulaca
5.5-7.5

Soybean
5.5-6.5
Primula
6-7.5

Spinach
6-7.5
Rhododendron 
4.5-6

Strawberry
5-7.5
Roses
5.5-7

String Beans
6-7.5
Sedum
6-7.5


Sugar beet
6-7
Sunflower
6-7


Sunflower
6-7.5
Tulip
6-7


Sweet Potato
5.5-6
Viola
5.5-6.5


Tomato
5.5-6.5




Watermelon
5.5-6.5




Wheat
6-7




Specifications

pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.1 pH
Temperature Range 0.0 to 50.0°C / 32.0 to 122.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C /±1°F
pH Calibration automatic, at one or two points using standard buffers (pH 4.01, 7.01,10.01); one point calibration using quick calibration solution
Temperature Compensation automatic from 0 to 50°C (32 to 122°F)
Battery Type/Life 1.5V CR2032 (1) / approximately 1000 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
Weight 65 g (2.3 oz.)
Ordering Information HI98118 GroLine is supplied with protective cap, (3) HI50036 Quick Cal calibration sachets (20 ml), (1) HI700601 general purpose cleaning solution sachet (20 ml), (1) CR2032 battery, instruction manual, and quality certificate.
Warranty 1 year (probe 6 months)